General Information


Description

The Classroom Performance System (CPS™) is an integrated software and hardware solution. The hardware consists of radio frequency (RF) or infrared (IR) student response devices and a receiver (or hub). The CPS™ software provides the tools to create and deliver course-relevant questions while adhering to Standards. Students use their devices to respond to questions. The receiver transmits the students’ responses to the CPS™ software. CPS™ compiles and reports the students' performance results.


System Requirements


Minimum System Requirements:

 

Recommended:


Known Issues


General Operation

  • If you are using eInstruction® applications together, such as: Response, Workspace™, CPS, ExamView®, you will need to upgrade all of these applications to the latest released version in order for Device Manager to communicate properly among them.
  • With Windows XP, users will see an error message with the Microsoft wisptise.exe application when a DualBoard™ or Mobi™ is connected via USB. Microsoft has addressed this issue and an update is available for Windows XP SP2 systems.
    Please see the following KB articles for more information.

 

CPS

 

Device Manager


Installation Information


Installing the CPS software from the CPS CD

  1. Insert the CPS CD and the Install window should appear.
  2. Click the Install CPS or Install CPS PPT button / icon to start the installation.
  3. Follow the on-screen instructions to complete the installation of the software.

 


Release Notes


This section lists the corrections and enhancements made to the recent versions of the CPS software.

Release CPS 6.70.0942, CPS PPT 6.70.0934 February 2011

  • Enhancements

    • Implemented support of CPS Spark™ student response device which limits allowable question types, in mixed device environment, to only those supported by CPS Spark™ when device is detected

    • Automatically uploads session and attendance functionality when CPS™ is launched along with the Workspace™ application

    • Implemented support for Mobi View™ reports

    • Implemented additional exception handling for:

      • “IllegalStateException” in client applications

      • Saving a question that contains large image files

      • Skipping the unsupported question types in Student Managed Assessment (SMA) mode

    • CPS PPT:

      • Implemented support of CPS Spark™ student response device limiting allowable question types, in mixed device environment, to only those supported by CPS Spark™ when device is detected

  • Corrections

    • Implemented lesson delivery and reporting with ABCD/FGHJ and FGHJ/ABCD questions with Gen3 RF receiver

    • Corrected session summary report percentages when navigating to other Mobi™/Mobi View™ reports

    • Corrected issue with Higher Education CPS™ RF Gen2 RF devices automatically joining a Higher Education class without registration

    • Corrected the question percentage display error for Essay questions types

    • Resolved Correct/Incorrect feedback on student response devices when engaged in verbal mode

    • ExamView® Integration:

      • Corrected question percentage display - Not updated in content delivery tool bar when answer option is changed from charting window

      • Corrected sending response issue to multiple choice questions engaged from within ExamView® file

      • Resolved the handling of unknown questions in teacher-led mode and homework mode

    • Cornerstone Integration:

      • Corrected unclear warning message when first engaging a class without a Cornerstone roster

      • Fixed ability to engage vClicker℠ ME sessions when certain invalid characters exist within Cornerstone URL

    • CPS™ PPT:

      • Resolved issue with CPS™ PPT not finding receiver when launching PPT lesson

      • Corrected Higher Education CPS Pulse™ device issue with unregistered students with a leading 'r' in serial number when imported from Angel LMS

      • Corrected percentage display issue for previous verbal and Chalkboard questions

Includes Device Manager Release 6.70.636.0 February 2011

  • Enhancements

    • Mobi View™ Support

    • CPS Spark™ Support

    • RFCOM Firmware Update for DualBoard™

    • Updated Device Manager API Developer Experience: start-up documentation, Java documentation, code samples, more intuitive development interface

    • About box displays all installed eInstruction® software and version numbers

  • Corrections

    • If a firmware update fails all hot plug events will be disengaged until Device Manager is restarted

    • User is not able to enter answers or votes until question starts (resolved in Teacher Managed Mode as well)

    • Able to consistently have one channel activated in Response using PRS RF student response devices

    • Device Manager conflict resolution with Sprint Smart View and 3G Air Card while port # 64211 is in use

    • Ability to “Pan” page as opposed to “Change” page in Workspace™ using Softkey

    • As a GWB file is linked to Softkey, it successfully opens from within Workspace™

    • When discovering a new device the unlock button is disabled when the student response device is not locked

    • When a locked Mobi™ is assigned "Set Presenter" mode, the “Lock” icon in the Device Manager toolbar and menu item of Mobi™ (to the right) is now shown as locked

    • When the “Close” or “Exit CPS™” button is clicked the Exception error does not appear

    • Gen3 SRS devices display True/False questions correctly

    • Device Manager will now show Correct/Incorrect in the CPS Pulse™ device when a correct or incorrect answer for a numeric question type is "0"

    • Text messages with special characters are received correctly

    • When engaging an unsupported question type in CPS™ for Mac the correct messaging is displayed

    • Device Manager for MAC software versions detects if more than one CPS Pulse™ RF receiver exists and is functioning

    • While running Device Manager at activity monitor level, only one instance of Device Manager appears

    • When restarting Device Manager while the calibration window is open, Device Manager does not lock up

    • After a Gen 3 CPS Pulse™ receiver firmware upgrade, all device properties are accessible and working without restarting Device Manager (*If using firmware version .54 and lower, the user will experience disruption and be required to manually join.)


Release 6.60.0016 November 2010

  • No Changes

Includes Device Manager Release 6.60.13.0 November 2010

  • Enhancements

    • Added an enhancement to prevent duplicate questions

  • Corrections

    • Fixed a problem with Device Manager locking up when logging off the system on Windows

    • Fixed a problem discovering devices after a user has logged off or shut down the system

    • Fixed a problem with Device Manager hanging while trying to discover serial devices

    • Fixed a problem that caused Device Manager to crash when a Mac system comes out of Sleep mode with a Mobi attached


Release 6.59.0018 September 2010

  • No Changes

Includes Device Manager Release 6.59.16.0 September 2010

  • Enhancements

    • Added support to SMA mode that would allow clickers to engage questions that contains a large number of characters

    • Added an enhancement to prevent clicker responses from being lost

    • Added an enhancement to improve the performance of clicker responses


Release 6.58.0001 August 2010

  • Corrections

    • Addressed issue where CPS would not engage the receiver if Device Manager is not already running

Includes Device Manager Release 6.58.1.0 August 2010

  • Enhancements

    • Added support for User Directories that are mapped to a network location

    • Added the ability to detect virtual serial ports and determine whether or not they should be used during device discovery


Release CPS 6.56.58, CPS PPT 6.56.81 June 2010

  • Corrections

    • Fixed the issue related to bottom of the slide show (when PPT lesson is engaged) being covered by the response grid

    • Fixed the issue related to CPS content delivery window staying opened behind verbal engage bar

    • CPS PowerPoint:

      • Fixed the issue of inability to send votes when vClicker is enabled and when the session / slideshow is started on a non-question slide

      • Enabled attendance feature, by adding take attendance icon on the new toolbar

Includes Device Manager Release 6.56.9.0 June 2010

  • Enhancements

    • Added new CPS Pulse Hub Firmware version 53

    • Added new CPS Pulse Clicker Firmware version 54

  • Corrections

    • Fixed a problem with the Http API not reading data from the client over 4096 bytes


Release CPS 6.55.762, CPS PPT 6.55.922 May 2010

  • Enhancements

    • Implemented Mobi reporting features for all new questions

    • Enhanced the KWIK screen in delivery options to show Instructors the reports are skipped in the Mobi for certain question types.

    • Implemented print questions and preview functions in lesson for Short Answer and Essay question types

    • CPS PowerPoint:

      • Redesigned the Toolbar to improve its appearance and flexibility

      • Improved slideshow navigation

      • Added the ability to use PowerPoint’s native transitions between slides

      • Slideshow now displays on the entire page

      • Updated the Ballot Grid to make more user friendly and less noticeable when not in use

      • Added functionality so when the user starts CPS™ PPT, and opens a .ppt or .pptx with a CPS™ questions, the toolbar appears and the slideshow starts automatically

      • Added delay auto start functionality so a time delay can be set before a question automatically starts

      • Added to ability for the user to easily adjust the font size during question delivery (slideshow)

      • Added the ability to add graphics to PowerPoint slides that contain CPS questions

  • Corrections

    • Improved the performance when engaging a lesson using Gen2/Pulse receiver

    • Fixed the problems with sessions not merging correctly

    • Fixed the font sizing issues in question author window.

    • Corrected the issue of the Content Deliver window staying on top of the screen after the text field in the Charting Window has been selected

    • Fixed the problem of the cross mark displaying at the end of SMA session when 'Indicate Correct response on Pads' option is selected

    • Fixed the problem of essay question being shown as incorrect on Mobi report when the answer is correct

    • Fixed the exception that occurs when engaging an empty ExamView lesson

    • Fixed the problem where an essay question displays as MC2 question when imported using XML format if the answers contains more than 140 characters

    • Fixed the problem of the answer for a Essay question displaying on the printed lesson

    • Fixed the issue that resulted in an exception error when the Download Assessments option was used with incorrect Cornerstone information

    • Fix the issue of pad ids repeating when syncing classroom rosters from Cornerstone

    • Fixed the problem of the "Send Session Results to Cornerstone" feature being enabled when Cornerstone is not enabled in CPS

    • Fixed the problem of the Cornerstone Login... option not showing as enabled after selecting the "Enabled Cornerstone" checkbox

    • Fixed the problem of not correctly importing WebCT class into CPS

    • Fixed the problem of class importing failing if one HE class is expired

    • Fixed the problems that produced the “IsCorrectAnswer:-- value:” error message when running Study Guide-Class Summary reports

    • CPS PowerPoint:

      • Fixed issues that affected the speed and responsiveness of the application

      • Eliminated the flashes during question delivery (slideshow)

Includes Device Manager Release 6.55.267.0 May 2010

  • Enhancements

    • Added full-featured firmware update functionality to Device Manager which includes Mobi Teacher, Mobi Learner, Mobi Hub, Pulse Hub, and Dual Board

    • Improved the Device Discovery process

    • Added hot-plug events for virtual serial devices; CPS RF Receiver, Interwrite Learning RF Receiver.

    • Enhanced Device Manager’s ability to communicate by allowing it to communicate on any random open port assigned by operating system

    • Added HTTP Server to Device Manager API, so Device Manager will now accept POST messages

    • Added the option to allow the user to store device preferences in a local or global directory. The user will be able to update through Device Manager Preferences.

  • Corrections

    • Fixed issue so Device Manager no longer hangs while discovering serial devices on Virtual COM ports used by other devices or software

    • Resolved issues which contributed to student responses being dropped

    • Fixed a problem with SRS Receivers getting disconnected

    • Fixed a problem with SRS Receivers failing to reconnect after multiple discoveries


Release CPS 6.52.1 March 2010

Includes Device Manager Release 6.52.1.0 March 2010

  • Corrections

    • Fixed a problem with SRS Receivers getting disconnected

    • Fixed a problem with SRS Receivers failing to reconnect after multiple discoveries


Release CPS 6.51.2 February 2010

·         Corrections

o     Fixed various usability problems

Includes Device Manager Release 6.51.2.0 February 2010

·         Corrections

o    Fixed various usability problems


Release CPS 6.50.252 - CPS PPT 6.50.264 January 2010

·          Enhancements

o    Added support for Windows XP 64 bit, Windows 7 32 bit and Windows 7 64 bit Operating systems

o    Added Essay answer question types (140 character text response)

o    Added Homework mode support for CPS™ Pulse clickers

o    Added Cornerstone integration enhancements

o    Added auto discovery of connected devices while CPS/CPS PowerPoint starts up

·         Corrections

o    Fixed issues related to ExamView integration and recalculate function

o    Fixed issues related to chart control and exception errors with closing chart

o    Reduce the time delay in showing engage toolbar

o    Fixed issues related to chalkboard and clearing questions after selecting question type

o    Fixed issues related to Cornerstone and vClicker integration

o    Fixed issues related to Workspace integration and the verbal toolbar going behind Workspace

o    Fixed issue with “Show Large Screen” being disabled after asking CPS™ questions through Workspace integration

o    Fixed several issues related to inaccurate Report data

o    Fixed Cricket detection problem when using PRS RF receiver

o    Fixed data collection and receiver communication problem in CPS™ PPT

Includes Device Manager Release 6.50.146.0 January 2010

·          Enhancements

o    Added support for Windows 7, Mac 10.6.x, Mac 10.5.8, and Ubuntu 8.04 - 64bit

o    Added 140 character support and firmware update for Pulse clickers

o    Added language strings for Pulse clickers

o    Added CPS Gen 1 IR Round and Blue Receivers support - other Gen 1 versions in different color and shape not supported beyond CPS 5.X

o    Added ability for client applications start device discovery

o    Added perpetual license for Avatana Bluetooth support

o    Added Essay answer question types

·         Corrections

o    Fixed problems with pen button assignment and events

o    Fixed problems with device connections and states

o    Fixed problems with discovering devices while collecting responses

o    Fixed problems with detecting 17" iPanel on Mac

o    The System Tray context menu now updates the menu items without requiring a restart. On Linux, the System Tray menu is now accessible using a single left click

o    Fixed issues with Mobi Teacher report corruption


Release CPS 6.10.1047 / CPS PPT 6.10.1047 October 2009


Release CPS 6.00.0975 / CPS PPT 6.00.0962 September 2009

Release CPS 6.00.0761 / CPS PPT 6.00.0835 August 2009

 

Device Manager: